View the PDF version Google Docs PDF Viewer
CITY OF MUSKEGON HISTORIC DISTRICT COMMISSION REGULAR MEETING DATE OF MEETING: Tuesday, April 1, 2025 TIME OF MEETING: 4:00 p.m. PLACE OF MEETING: Conference Room 204, City Hall AGENDA I. Call to Order II. Approval of Minutes of the February 27, 2025 special meeting and March 4, 2025 regular meeting III. Old Business IV. New Business Case 2025-07 – 349 W. Webster – New Dormers, Skylights, Gable Roof, and Chimney Removal Case 2025-08 – 1095 3rd – Remodel and Building Addition Case 2025-09 – 1314 Peck – Window Replacement and Copper Roof Case 2025-10 – 1184 7th – Installation of Cornice V. Other Business Historic Preservation Tax Credit Workshop VI. Adjourn AMERICAN DISABILITY ACT POLICY FOR ACCESS TO OPEN MEETINGS OF THE CITY OF MUSKEGON AND ANY OF ITS COMMITTEES OR SUBCOMMITTEES To give comment on a live-streamed meeting the city will provide a call-in telephone number to the public to be able to call and give comment. For a public meeting that is not live-streamed, and which a citizen would like to watch and give comment, they must contact the City Clerk’s Office with at least a two-business day notice. The participant will then receive a zoom link which will allow them to watch live and give comment. Contact information is below. For more details, please visit: www.shoreline- city.com The City of Muskegon will provide necessary reasonable auxiliary aids and services, such as signers for the hearing impaired and audio tapes of printed materials being considered at the meeting, to individuals with disabilities who want to attend the meeting with twenty-four (24) hours’ notice to the City of Muskegon. Individuals with disabilities requiring auxiliary aids or services should contact the City of Muskegon by writing or by calling the following: Ann Marie Meisch, MMC, City Clerk at 933 Terrace Street, Muskegon, MI 49440 or by calling 231-724-6705 or emailing clerk@shorelinecity.com 1 II. APPROVAL OF MINUTES Approval of Minutes of the special meeting of February 27, 2025 and the regular meeting of March 4, 2025. III. OLD BUSINESS None 2 IV. NEW BUSINESS Case 2025-07 – 349 W. Webster – New Dormers, Skylights, Gable Roof, and Chimney Removal Applicant: 349 West Webster LLC District: National Register Current Function: Vacant Discussion The applicant is seeking approval to construct two new dormers on the east and west sides of the building’s roof, four new 5’x4’ skylights, and a new gable roof between the existing roof and the clock tower. The applicant is also requesting approval to demolish two small chimneys near the clock tower, if necessary. The dormers would be used to vent HVAC items, and the new gable roof would provide additional headroom in the interior space leading to the clock tower. Staff approved replacement of the roof shingles in October 2024, but construction/demolition of the items included in this request are proposed to be completed concurrently with the roofing work to avoid any future penetrations in the new roof. See Attachment A for additional drawings (please note that the applicant is only seeking approval for the items listed here at this time). View from the corner of 3rd Street and Webster Avenue, looking south. 3 View from 3rd Street, looking southwest. View from 4th Street, looking northeast. 4 Standards DESIGN GUIDELINES FOR NEW CONSTRUCTION Although a significant amount of the Commission’s work is centered on historic structures, the construction of new structures on vacant lots within historic districts is permitted and encouraged. However, those professionals designing new structures should strive for excellence in design whether small individual infill construction within the existing historic district blocks, or larger independently sited projects. New structures should be in keeping with the existing historical character of the neighborhood or district with a design that is compatible with the size, scale, material, and color of the surrounding buildings and landscaping. Good design which responds positively to its surroundings can be done in several different ways; therefore, it is impossible to develop specific interpretations which will apply in all cases. Every site has its own design opportunities. The following design recommendations shall be used by the Historic District Commission in evaluating requests for new construction within the districts. These basic criteria should be a part of any proposed design brought before the Commission for approval. Recommended Not Recommended Height - Relating the overall height of new Height - Introducing new construction that construction to that of adjacent structures. As varies greatly in height (too high or too low) a general rule, construct new buildings to a from older buildings in the vicinity. Extreme height roughly equal to the average height of differences in building heights will have a existing buildings from the historic period on detrimental visual effects on the appearance and across the street. of surrounding property. Scale - Relating the size and proportions of Scale - Creating buildings that in height, new structures to the scale of adjacent width, or massing violate the existing scale of buildings. Although a building may be much the area. The new building should not disrupt larger than its neighbors in terms of square the scale and rhythm of the streetscape, footage, it should maintain the same scale although it might be appropriate in a different and rhythm as the existing buildings. location. Massing - Breaking up uninteresting box-like Massing - Introducing single, monolithic forms into smaller, varied masses such as are forms that are not relieved by variations in common on most buildings from the historic massing. Box-like facades and forms are period. Variety of form and massing are intrusive when placed in a streetscape of elements essential to the character of the older buildings that have varied massing and streetscape in historic districts. For example, facade articulation. if an infill site is large, the mass of the facade can be broken into a number of small bays. Directional Expression - Relating the Directional Expression - Creating strongly vertical, horizontal, or non-directional facade horizontal or vertical facade expressions character of new buildings to the unless compatible with the character of predominant directional expression of nearby structures in the immediate area. A new buildings. Horizontal buildings can be made building that does not relate well to its to relate to the more vertical adjacent neighbors or to the rhythm of the streetscape structures by breaking the facade into smaller because of an unbroken horizontal facade 5 masses that conform to the primary should be avoided. expression of the streetscape. Setback - Maintaining the historic facade Setback - Violating the existing setback lines of streetscape by locating front walls of pattern by placing a new building in front of new buildings in the same plane as the or behind the historic facade line. Placing facades of adjacent buildings. If exceptions buildings at odd angles to the street, unless in are made, buildings should be set back into an area where diverse siting already exists, the lot rather than closer to the street. If even if property setback is maintained, existing setbacks vary, new buildings should should be avoided. conform to historic siting patterns. Sense of Entry - Articulating the main Sense of Entry - Introducing facades with no entrances to the building with covered strong sense of entry. Side entries or entries porches, porticos, and other pronounced not defined by a porch or similar transitional architectural forms. Entries were historically element result in an incompatible "flat" first- raised a few steps above the grade of the floor facade. property and were a prominent visual feature of the street elevation of the building. Roof Shapes - Relating the roof forms of the Roof Shapes - Introducing roof shapes, new buildings to those found in the area. pitches, or materials not traditionally used in Although not entirely necessary, duplication the area. of the existing or traditional roof shapes, pitches, and materials on new construction is one way of making new structures more visually compatible. Rhythm of Openings - Respecting the Rhythm of Openings - Introducing recurrent alteration of wall areas with door incompatible facade patterns that upset the and window elements in the facade. Also rhythm of openings established in considering the width-to-height ratio of bays surrounding structures. For example, glass in the facade. The placement of openings walls and window and door shapes and with respect to the facade's overall locations which are disrespectful to the composition, symmetry or balanced adjoining buildings. symmetry should be carefully studied. Design Expression - Composing the Design Expression - Violating the existing materials, textures and colors of the new character of the district by introducing non- building facade to compliment adjacent compatible materials, textures, colors, facades and relating details and decorations details, and decoration on new buildings. of the new building to those of existing surrounding buildings. Imitations - Accurate restoration of or Imitations - Replicating or imitating the visually compatible additions to existing styles, motif, or details of older periods. Such buildings and former construction, attempts detract from the character of the contemporary architecture that well district by compromising what is truly represents our own time yet, enhances the historic. nature and character of the historic district. 6 7 8 Deliberation I move that the HDC (approve/deny) the request to construct two new dormers on the east and west sides of the building’s roof, four new 5’x4’ skylights, and a new gable roof between the existing roof and the clock tower as depicted in the drawings included in the April 1, 2025 HDC staff report and to demolish two small chimneys near the clock tower, if necessary as long as the work meets all zoning requirements and the necessary permits are obtained. 9 Case 2025-08 – 1095 3rd – Remodel and Building Addition Applicant: Muskegon Midtown Center District: Houston Current Function: Vacant Discussion The applicant is seeking approval to remodel the exterior of the existing building and construct a new two- story building addition along Houston Avenue. In late 2024, the HDC previously approved exploratory demolition on the exterior of the building, and informally discussed preliminary design concepts for this project at the January 7, 2025 regular meeting. See Attachment B for additional drawings. View from 3rd Street, looking west. Rendered view of proposed building remodel and addition from 3rd Street, looking west. Standards See Design Guidelines for New Construction in Case 2025-07, above. 10 Deliberation I move that the HDC (approve/deny) the request to remodel the exterior of the existing building and con- struct a new two-story building addition along Houston Avenue as depicted in the drawings included in the April 1, 2025 HDC staff report as long as the work meets all zoning requirements and the necessary permits are obtained. 11 Case 2025-09 – 1314 Peck – Window Replacement and Copper Roof Applicant: April Sturm District: McLaughlin Current Function: Residential Discussion The applicant is seeking approval to reconstruct the bay window on the north side of the house, replacing the center window with a new window of the same dimensions with a single glass pane, and replacing the bay’s existing painted aluminum roof with a copper roof. View from Peck Street, looking southeast. 12 Bay window on north side of house. 13 Standards WINDOW, DOOR, AND EXTERIOR WOODWORK STANDARDS AND GUIDELINES (Abbreviated) General These guidelines pertain only to proposed changes to the structure and do not affect existing construction. These guidelines are primarily directed toward the front and side elevations of the structure. Greater variances and more leniency may be extended toward proposed changes to the rear elevation of the building by the Commission. All desired or proposed changes should be referred to the Historic District Commission for consideration. Extenuating circumstances, the effect upon the architecture of the particular structure together with the general effect upon the surrounding structures, variables in architectural design, or the effect upon usage and viability of the structure could dictate a variance from these guidelines. No exterior doors, windows, or exterior woodwork shall be altered, removed, relocated, or added without Historic District Commission approval. Existing exterior window or door casings, sills, and caps shall not be altered from the original design or appearance. Damaged or deteriorated wood shall be repaired as a first course of action. When repair is not possible, elements shall be replaced with matching wood members. Damaged or deteriorated wood elements may be replaced or covered with formed aluminum or vinyl, subject to Commission approval and provided that the original profile of the woodwork is not altered or changed. Primary Windows Existing damaged or deteriorating window frames and sash shall be repaired as a first course of action. When repair is not possible, elements shall be replaced with matching wood members. Metal or vinyl replacement windows may be acceptable provided they match the original windows in design and type and that they consist of or are painted an appropriate color. Bare metal finishes generally will not be acceptable. The size of glass lites and muntin arrangements shall not be altered without Commission approval. Special glazing, such as stained or leaded art glass, shall not be removed without Commission approval. Unusual decorative windows such as Palladian windows, oriels, bays, Gothic arch or segment tops, etc. shall not be removed or altered. ROOFING GUIDELINES (abbreviated) The design of all roofing materials used on sloped roofs and structures within the historic districts shall maintain the appearance of the original roofing materials and be appropriate to the style and period of the structure. Materials shall be selected and installed in accordance with the guidelines as follows: … Metal Roofing for flat or low pitched decks or standing rib metal on sloping roofs, where terne, copper, or other metal roofing has been used previously, shall be acceptable. Stamped metal roofing where the stamped pattern resembles the original roofing material shall be acceptable. Standing-seam metal roofing where not originally installed is not generally permissible. 14 Deliberation I move that the HDC (approve/deny) the request to reconstruct the bay window on the north side of the house, replacing the center window with a new window of the same dimensions with a single glass pane, and replacing the bay’s existing painted aluminum roof with a copper roof as long as the work meets all zoning requirements and the necessary permits are obtained. 15 Case 2025-10 – 1184 7th – Installation of Cornice Applicant: Justin Van Hook District: Clay-Western Current Function: Residential Discussion The applicant is seeking approval to remove the existing clay coping on the parapet wall on the 7th Street elevation and install black metal flashing and a new cornice. The remaining clay coping on the other three elevations will be replaced following repairs to the flat roof. View from 7th Street, looking northeast. View from 7th Street, looking north. 16 View from 7th Street, looking east. Examples of proposed cornice. Standards No specific standards apply. 17 Deliberation I move that the HDC (approve/deny) the request to remove the existing clay coping on the parapet wall on the 7th Street elevation and install black metal flashing and a new cornice as long as the work meets all zoning requirements and the necessary permits are obtained. V. OTHER BUSINESS Historic Preservation Tax Credit Workshop – On Tuesday, April 22, 2025 the City of Grand Rapids is hosting a free Historic Preservation Tax Credit Workshop with Mara Lancaster, Historical Architect with the State Historic Preservation Office (SHPO). The workshop will run from 6:00pm – 7:30pm at Cornerstone Church at 48 Lafayette Avenue SE in Grand Rapids. VI. ADJOURN 18 Attachment A 19 Improving lives through design. GENERAL ROOF PLAN NOTES 1. ALL ROOF-MOUNTED EQUIPMENT AND PENETRATIONS ARE NOT SHOWN. COORDINATE QUANTITIES AND LOCATIONS WITH OTHER DISCIPLINES. 2. PROVIDE SADDLES AT OBSTRUCTIONS THAT RESTRICT THE FLOW OF WATER TO DRAINAGE SYSTEM. # ROOF PLAN KEYNOTES 1. EXISTING ROOFING TO BE REMOVED TO SUBSTRATE. DAMAGED SUBSTRATE TO BE REMOVED AND REPLACED. INSTALL NEW ASPHALT ROOFING SYSTEM (SHINGLES) WITH PROPER UNDERLAYMENT. 2. CHIMENY TO BE DEMOLISHED. INFILL OPENING WITH WOOD FRAMING AND ROOF SUBSTRATE. 3. REPAIR / REPLACE DAMAGED EXISTING COPPER GUTTERS AND DOWNSPOUTS. MATCH EXISTING 4. NEW 5'-0" x 4'0" SKYLIGHT 5. NEW MECHANICAL PENTHOUSE DORMER - HIP ROOF 6. NEW ROOF ACCESS - GABLE ROOF 316 Morris Avenue Suite 410 Muskegon, MI 49440 P. 231.722.3407 F. 231.722.2589 PRH-2 4 1 HACKLEY CASTLE RENOVATION 1 1 1 1 349 WEBSTER, MUSKEGON, MI 349 WEBSTER, LLC 8" / 1'-0" 8" / 1'-0" 1 NEW DOOR AND STEEL GRATE 1 2 2 LANDING 6 4 4 1 1'-0" / 1'-0" 1'-0" / 1'-0" CHIMNEY CHIMNEY 1'-0" / 1'-0" 1'-0" / 1'-0" PRH-2 1 3 PRH-2 PROJECT NUMBER 2021.0176 1'-0" / 1'-0" 1'-0" / 1'-0" ISSUANCE NO. DATE DESCRIPTION 5 5 1 2025.03.18 HISTORIC PRELIMINARY REVIEW Autodesk Docs://349 Webster LLC Hackley Square - 2021.0176/2021_0176 ARCH_Renovation 2024.rvt 4 4 1 1 1 F O R N O T U CT I O N S T R C ON Copyright © 2024 HDJ Inc. All Rights Reserved 1 1 1 HISTORIC 3/18/2025 4:21:02 PM 1 2 1 PRH-1 OVERALL ROOF PLAN 1/8" = 1'-0" PRH-2 A4.1 PRH-1 Improving lives through design. GENERAL ELEVATION NOTES (APPLIES TO ALL ELEVATION DRAWINGS) 1. PROVIDE COMPOSITE TRIM BLOCKS AT ALL EXTERIOR PENETRATIONS, MOUNTING LOCATIONS, SCUPPERS, LOUVERS, ETC. ON SIDING. 2. PAINT ALL EXTERIOR PENETRATIONS, LOUVERS, VENTS, PIPES, COVERS, ETC TO MATCH EXISTING WALL COLOR/FINISH. 3. 7 # EXTERIOR ELEVATION KEYNOTES 1. LOWER EXISTING GRADE AND EXPOSE WALLS 2. NEW RETAING WALL AND WALKWAY 3. NEW DOORS 4. NEW TRANSOM WINDOW 5. NEW WINDOW SYSTEM 6. MECHANICAL EQUIPMENT - SEE MECHANICAL 7. NEW ASPHALT ROOFING SYSTEM TOWER ROOF TOWER ROOF 8. NEW DORMER 181' - 1" 181' - 1" 9. LOUVER - PAINTED TO MATCH TRIM GLASS INFIL CHIMNEY GLASS INFIL 10. 8" COMPOSITE TRIM - PAINTED TO MATCH NEW SHINGLES 11. NEW SKYLIGHT 316 Morris Avenue TOWER - CLOCK NEW GABLE TOWER - CLOCK 172' - 8 1/4" ROOF 172' - 8 1/4" Suite 410 CHIMNEY CHIMNEY Muskegon, MI 49440 TOWER THREE TOWER THREE P. 231.722.3407 160' - 10 1/4" 160' - 10 1/4" F. 231.722.2589 TOWER TWO TOWER TWO 151' - 10" 151' - 10" 8 8 7 7 TOWER ONE TOWER ONE 5 142' - 10 1/2" 10 142' - 10 1/2" MEZZANINE 138' - 0" OPEN OPEN OPEN BALCONY BALCONY BALCONY FOURTH FLR 11 FOURTH FLR 128' - 10" 9 128' - 10" 5 4 3 2 THIRD FLR THIRD FLR 5 114' - 5" 114' - 5" 4 3 1 HACKLEY CASTLE RENOVATION SECOND FLR SECOND FLR 100' - 0" 100' - 0" VESTIBULE VESTIBULE 1 91' - 6 1/4" 91' - 6 1/4" FIRST FLR FIRST FLR 2 2 87' - 10" 87' - 10" LOWER GRADE - SEE SITE PLAN LOWER GRADE - SEE SITE PLAN 4 NORTH ELEVATION 3 EAST ELEVATION 349 WEBSTER, MUSKEGON, MI 349 WEBSTER, LLC PRH-2 1/16" = 1'-0" PRH-2 1/16" = 1'-0" TOWER ROOF 181' - 1" CHIMNEY ENCLOSE WITH GLASS NEW GABLE TOWER - CLOCK PROJECT NUMBER 2021.0176 ROOF 172' - 8 1/4" ISSUANCE CHIMNEY CHIMNEY NO. DATE DESCRIPTION 7 5 1 2025.03.18 HISTORIC ENCLOSED WITH GLASS TOWER THREE TOWER THREE PRELIMINARY 160' - 10 1/4" 160' - 10 1/4" REVIEW 8 EXISTING ELEVATOR 7 TOWER TWO TOWER TWO PENTHOUSE 7 7 151' - 10" 151' - 10" ENCLOSE Autodesk Docs://349 Webster LLC Hackley Square - 2021.0176/2021_0176 ARCH_Renovation 2024.rvt 8 WITH GLASS 7 TOWER ONE TOWER ONE 5 142' - 10 1/2" 11 142' - 10 1/2" OPEN BALCONY 9 5 10 5 FOURTH FLR FOURTH FLR 128' - 10" 4 128' - 10" 3 THIRD FLR THIRD FLR F O R N O T U CT I O N 114' - 5" 114' - 5" S T R C ON 4 3 SECOND FLR SECOND FLR 100' - 0" 100' - 0" 5 4 4 4 5 Copyright © 2024 HDJ Inc. All Rights Reserved VESTIBULE VESTIBULE 91' - 6 1/4" 3 91' - 6 1/4" 3 FIRST FLR FIRST FLR 87' - 10" 87' - 10" HISTORIC EXTERIOR ELEVATIONS 2 SOUTH ELEVATION 1 WEST ELEVATION 3/18/2025 4:29:56 PM PRH-2 1/16" = 1'-0" PRH-2 1/16" = 1'-0" PRH-2 Attachment B 20 R F O R IO N T T NO RUC N ST CO 3 Parking Facing A-201 3/32" = 1'-0" Andersen E Series 8' X 5' GLIDING WINDOWS: QTY: 63 6' X 5' GLIDING WINDOWS: QTY: 40 3' X 5' FIXED WINDOWS: QTY: 5 TOTAL Andersen E 108 Silverline V3 Gliding Windows NorthStar Windows: Series 1000 Double Slider Liftout - Double Pane with white interior/Espresso exterior 78" x 60" QTY: 103 24" X 60" QTY: 20 36 X 60" QTY: 5 TOTAL NorthStar QTY: 128 7.0 6.0 5.0 4.0 3.0 2.0 1.0 PARAPET HEIGHT 24' - 8" ROOF HEIGHT 22' - 8" 11'-4" LEVEL 2 11' - 4" 11'-4" MUSKEGON MIDTOWN CENTER LEVEL 1 0" 5 Facing Parking Lot to Southwest 2 3rd Street Elevation A-201 3/32" = 1'-0" A-201 3/32" = 1'-0" Muskegon Midtown Center LLC MUSKEGON, MI This drawing is an instrument of service and shall Houston Avenue Elevation COPYRIGHT © 2022 Short Elliott Hendrickson, Inc. remain the property of Short Elliott Hendrickson, Inc. 1 (SEH). This drawing, concepts and ideas contained All Rights Reserved herein shall not be used, reproduced, revised, or A-201 3/32" = 1'-0" retained without the express written approval of SEH. Submission or distribution of this drawing to meet official or regulatory requirements or for purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH. SEH Project 180390 Checked By ajr Drawn By S. Parker Project Status Issue Date DESIGN DEVELOPMENT 01/16/25 REVISION SCHEDULE REV. # DESCRIPTION DATE 3/19/2025 3:40:25 PM PROPOSED ELEVATIONS 4 Facing Parking/Alley A-201 3/32" = 1'-0" A-201 R F E D C B A 19'-2" 20'-1 1/2" 20'-1 1/2" 20'-2" 18'-6" O R IO N STAIR ELEV B03 MECHANICAL/ELECTRICAL T F T NO RUC B02 ROOM ST 16'-9" N UNEXCAVATED AREA UP CO (UNDER EXISTING GARAGE) 3'-9" 3'-9" 1.0 CORR STAIR 793.0 SF 19'-7" OFFICE OFFICE OFFICE 9'-7 1/2" 374.9 SF 185.2 SF 93.1 SF 2.0 10'-0" 10'-0" 5'-0" OFFICE STOR. 231.9 SF 8'-0" OFFICE 19'-0" 99.0 SF OFFICE OFFICE 10'-0" 10'-0" STOR. 10'-0" STOR. OFFICE 10'-0" 8'-0" 98.4 SF STOR. CORR 3.0 10'-0" OFFICE OFFICE 98.0 SF STOR. 10'-0" OFFICE CLASSROOM 19'-0" 1656.1 SF OFFICE OFFICE 10'-0" STOR. STOR. OFFICE MUSKEGON MIDTOWN CENTER 10'-0" 4.0 STOR. STOR. OFFICE OFFICE 10'-0" STOR. 113.6 SF 19'-0" Muskegon Midtown Center LLC STAIR 5.0 MUSKEGON, MI 19'-0" This drawing is an instrument of service and shall 6.0 COPYRIGHT © 2022 HACKLEY Short Elliott Hendrickson, Inc. remain the property of Short Elliott Hendrickson, Inc. (SEH). This drawing, concepts and ideas contained All Rights Reserved SQUARE herein shall not be used, reproduced, revised, or retained without the express written approval of SEH. 3055.7 SF Submission or distribution of this drawing to meet official or regulatory requirements or for purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH. 17'-6" SEH Project 180390 Checked By ajr Drawn By S. Parker Project Status Issue Date 7.0 DESIGN DEVELOPMENT 01/16/25 REVISION SCHEDULE REV. # DESCRIPTION DATE 3/19/2025 3:39:49 PM PROPOSED BASEMENT FLOOR PLAN A-104 E D C R TWO HOUR RATED WALLS 1600 AMP PDP 3 meter bank 5 O R IO N ELEC F 3'-6" T T meter bank 6 meter bank 7 meter bank 1 meter bank 2 6'-1" NO RUC ELEV meter bank 3 meter bank 4 N ST CO 133.1 SF 3'-5" STAIR 107.8 SF 1600 AMP PDP 1 1600 AMP PDP 2 2'-6" 10'-0" 10'-0" DN 3 ELECTRICAL ROOM FLOOR PLAN A-105A 3/16" = 1'-0" 6.0 4 A-201 3 F E D A-105A C B A 19'-2" 20'-1 1/2" 20'-2" 18'-6" FIRST FLOOR EXISTING BLDG: 12'-11" ENTRY/COMMON ELEV (14) 1-BD APTS 411-656 S.F. AREA 102 STAIR 100 103 26'-8" (2) 2-BD APTS 745-912 S.F. DN W 1.0 2 LEVEL 1+PROPOSED PLAN CALLOUT W A-105A 3/16" = 1'-0" STOR ADDITION: 1-BD STAIR 1-BD 24 UNITS - FIRST FLOOR STOR 1-BEDROOM APTS: 513 S.F. EA. UP 2.0 MUSKEGON MIDTOWN CENTER 195'-6 1/2" STOR 181'-11" 1-BD CORR 2 A-201 Muskegon Midtown Center LLC 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD STOR STOR. STOR STOR 599.7 SF 3.0 5 2-BD A-201 825.2 SF 16'-9" 1-BD W MUSKEGON, MI 4.0 W 1-BD 663.2 SF 2-BD This drawing is an instrument of service and shall COPYRIGHT © 2022 Short Elliott Hendrickson, Inc. remain the property of Short Elliott Hendrickson, Inc. 875.1 SF CORR (SEH). This drawing, concepts and ideas contained All Rights Reserved herein shall not be used, reproduced, revised, or 73'-9 1/2" retained without the express written approval of SEH. STAIR 5.0 W STAIR Submission or distribution of this drawing to meet 7'-10" ELEC official or regulatory requirements or for purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH. 3'-6" 20'-6 1/2" SEH Project 180390 Checked By ajr Drawn By S. Parker STAIR 6'-4 1/2" W 7'-10" Project Status Issue Date DESIGN DEVELOPMENT 01/16/25 6.0 15'-0" 11'-11 1/2" 11'-9 1/2" 12'-3" 11'-9 1/2" 14'-5" 2 1-BD 1-BD REVISION SCHEDULE A-105A 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD REV. # DESCRIPTION DATE 7.0 1 A-201 3/19/2025 3:39:58 PM PROPOSED FIRST FLOOR PLAN 1 LEVEL 1+PROPOSED PLAN - LAYOUT A A-105A 3/32" = 1'-0" A-105A R F O R IO N T T NO RUC N ST CO F E D C B A 1-BD ELEV SECOND FLOOR EXISTING BLDG: ELEC (15) 1-BD APTS 505-725 S.F. 1-BD 1-BD 1-BD 1.0 1-BD STAIR 6'-0" DN MUSKEGON MIDTOWN CENTER 2'-0" 1-BD ADDITION: 2.0 Muskegon Midtown Center LLC STOR STOR STOR 24 UNITS - FIRST FLOOR 1-BEDROOM APTS: 513 S.F. EA. CORR 2 1-BD A-201 STOR STOR 1-BD STOR 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 3.0 MUSKEGON, MI 5 3'-0" A-201 1-BD 1-BD 4.0 This drawing is an instrument of service and shall COPYRIGHT © 2022 Short Elliott Hendrickson, Inc. remain the property of Short Elliott Hendrickson, Inc. (SEH). This drawing, concepts and ideas contained STOR All Rights Reserved herein shall not be used, reproduced, revised, or retained without the express written approval of SEH. Submission or distribution of this drawing to meet 1-BD STOR official or regulatory requirements or for purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH. STOR 1-BD SEH Project 180390 Checked By ajr CORR Drawn By S. Parker STAIR STOR STOR STOR 5.0 STAIR STOR STOR Project Status Issue Date DESIGN DEVELOPMENT 01/16/25 REVISION SCHEDULE REV. # DESCRIPTION DATE 1-BD 6.0 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 1-BD 7.0 3/19/2025 3:40:07 PM PROPOSED SECOND FLOOR PLAN 1 A-201 1 LEVEL 2-PROPOSED PLAN A-106 A-106 3/32" = 1'-0"
Sign up for City of Muskegon Emails